The purpose of this amendment is to: 1. Attach the following documents related to contractor questions arising from the mandatory site visit: a) FA466126R0010 Q_A Final.pdf b) Dyess_AFB_Electrical_Study-Volume1 (Final Report)_Redacted.pdf c) Dyess_AFB, A-Sub Relay Settings.pdf d) Sub A Fdr A1 East Housing Relay.pdf e) Sub A Fdr A2 West Housing Relay.pdf 2. All other terms and conditions remain unchanged. This is a solicitation for the requirement of properly replacing the Substation Alpha Feeder Protection Relays at Building 11912 on Dyess AFB. The Contractor shall install (2) NEW GE 850 Feeder Protection Relays which are provided by the Government. The contractor shall install and wire in (2) new Feeder Protection Relays in accordance with NEC/ NETA standards. The Contractor shall program the (2) new Feeder protection relays to match programming of the previously installed GE 760 relays, via settings provided by the Electrical shop and test functionality without load. The Contractor shall coordinate with the Electrical shop prior to energizing the primary voltage for testing and commissioning. The Contractor shall commission and test the two new relays with full base load once installed with witnesses from Electrical, Contracting and R&O. The Contractor will coordinate with the Electrical Shop before conducting any power outages for acceptance tests if needed. Please see attachments for details.
Classifications
Documents (10)
- Statement of Work - Redacted.pdf.pdf146 KBNot yet available
- Solicitation Amendment FA466126R00100002 SF 30.pdf.pdf398 KBNot yet available
- Dyess_AFB_Electrical_Study-Volume1 (Final Report)_Redacted.pdf.pdf48.1 MBNot yet available
- Sub A Fdr A1 East Housing Relay.pdf.pdf167 KBNot yet available
- Wage Determination.pdf.pdf166 KBNot yet available
- FA466126R0010 Q_A Final.pdf.pdf142 KBNot yet available
- Solicitation FA466126R0010_Redacted.pdf.pdf15.0 MBNot yet available
- Dyess_AFB A-Sub Relay Settings.pdf.pdf105 KBNot yet available
- Sub A Fdr A2 West Housing Relay.pdf.pdf168 KBNot yet available
- Solicitation Amendment FA466126R00100001 SF 30.pdf.pdf396 KBNot yet available
Contacts
Similar contracts
- Roush Lake Elevator RepairsDue Sep 21, 2026
- Industrial Fan Maintenance and Repair ServicesMarylandDue Sep 21, 2026
- Fire Extinguisher ServiceGeorgiaDue Sep 21, 2026
- Exhibit Preventative Maintenance and Ad Hoc Repairs at the National Archives MuseumDistrict of Columbia
- Notice of Intent for Material Handling Equipment (MHE) maintenance and repair serviceTexasDue Sep 25, 2026
- USDA Forest Service Oconaluftee Job Corps Center annual Generator MaintenanceNorth CarolinaDue Sep 25, 2026