J012--575 Fire System Inspection & Repairs - one year only

VETERANS AFFAIRS, DEPARTMENT OF
Response deadline
Jun 29, 2026
Closed
Date posted
Jun 25, 2026

Description

Q&A Solicitation # 36C25926Q0519 The purpose of this amendment is to: Provide answers to questions received under solicitation 36C25926Q0519. To provide the Joint Commission review tool and clarification document to add awareness for prospective contractors regarding the standards for completing repairs and inspections (see attached). All offers are to be emailed to heather.chase2@va.gov and received no later than 12:00pm (noon) MT on June 29, 2026. Questions and Answers below are referencing RFQ 36C25926Q0519: Q. Will the Government please provide the number of Wet Systems per building? B1: 1 B5: 1 B6: 1 B7: 1 B8: 1 B12: 1 B13: 1 B20: 1 B22: 1 B33: 1 B34: 1 B36: 1 B45: 1 . Q. What is the total number of Dry Systems per building? A. Not in scope of the required repairs. Q. What is the total number of Pre-Action Systems? A. None, station is wet-piped. Q. What is the total number of Deluge Systems? A. Not in scope of required repairs. Q. What is the total number of Backflow Preventers?. A. Not in scope of required repairs. Q. What is the total number of Fire Pumps? A. Not in scope of required repairs. Q. What is the total number of Control Valves? A. Please see CLIN 3 (page 5 & 6) of Attachment 1 - SOW. Q. What is the total number of Flow Switches? A. Please see CLIN 3 (page 5 & 6) of Attachment 1 - SOW. Q. What is the total number of Pressure Regulating Valves PRV? A. Not in scope of required repairs.

Classifications

Documents (28)

  • CLIN 03 Bldg 7- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf81 KB
    Download
  • CLIN 03 Bldg 1- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf281 KB
    Download
  • CLIN 03 Bldg 33- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf61 KB
    Download
  • CLIN 03 Bldg 8- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf85 KB
    Download
  • CLIN 01 VA -Grnd Junc CLC Kitchen Hood 2121 N Ave FAIL.pdf
    .pdf551 KB
    Download
  • 36C25926Q0519 0002.docx
    .docx26 KB
    Download
  • 36C25926Q0519.docx
    .docx50 KB
    Download
  • CLIN 03 Bldg 6- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf81 KB
    Download
  • CLIN 03 Bldg 22 Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf62 KB
    Download
  • CLIN 03 Bldg 37- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf63 KB
    Download
  • CLIN 02 VA B37 Audible Deficiencies.pdf
    .pdf55 KB
    Download
  • CLIN 03 Bldg 5- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf78 KB
    Download
  • CLIN 03 Bldg 36- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf63 KB
    Download
  • CLIN 03 Bldg 35- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf75 KB
    Download
  • Attachment 2 - Price Schedule.docx
    .docx16 KB
    Download
  • CLIN 02 VA Hosp - Grand Junction Battery List 2025.pdf
    .pdf86 KB
    Download
  • CLIN 03 Bldg 13- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf77 KB
    Download
  • Attachment 1 - SOW.docx
    .docx52 KB
    Download
  • CLIN 03 Bldg 20- Quarterly Sprinkler 12-22-25 Fail.pdf
    .pdf64 KB
    Download
  • 36C25926Q0519 0003.docx
    .docx32 KB
    Download
  • CLIN 01 VA- NFS-Kitchen Hood 2121- N Ave-FAIL.pdf
    .pdf552 KB
    Download
  • CLIN 03 Bldg 45- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf63 KB
    Download
  • Life Safety and Environment of Care Document List and Review Tool 10-2023.pdf
    .pdf257 KB
    Download
  • VHA-Joint Commission Clarification Document effective 1-October-2023.pdf
    .pdf3.2 MB
    Download
  • Attachment 2 - Revised Price Schedule.docx
    .docx16 KB
    Download
  • CLIN 03 Bldg 12- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf62 KB
    Download
  • CLIN 03 Bldg 34- Quarterly Sprinkler 12-22-25 FAIL.pdf
    .pdf64 KB
    Download
  • 36C25926Q0519 0001.docx
    .docx28 KB
    Download