Wiesbaden Commissary Total Maintenance Services
- Response deadline
- Aug 21, 2026 Due in 7 days
- Date posted
- Aug 13, 2026
- Source
- Open notice
Description
Amendment 4: A.15.01.01(HQC01026QE021 A0004): Updated pricing worksheet by removing contractor workorder system pricing from the worksheet and added a line in the PM section miscellaneous item for inventory variation. A.15.01.03.10 Solicitation Attachment 1 Pricing Worksheet is renamed to A.15.01.03.10 Updated Solicitation Attachment 1 Pricing Worksheet Amendment 3 A.15.01.01 (HQC01026QE021 A0003): Removing CLINs 0004, 1004, and 2004 from the solicitation and resultant contract, and answering questions received from industry. Amendment 2: A.15.01.01 (HQC01026QE021 A0002): Changing CLINs 0004, 1004, and 2004 from priced to not priced, providing a site visit map, and answering questions received from industry. Amendment 1: A.15.01.01 (HQC01026QE021 A0001): Correcting the Solicitation Helpdesk Link. See attached for more information. The Defense Commissary requires a commercial contractor to provide comprehensive maintenance services at the Wiesbaden commissary facility and equipment in Germany. This is a non-personal services requirement where the contractor manages their own workforce to keep all building systems, infrastructure, and food handling equipment safe, compliant and continously operational. The contractor is responsible for three tiers of facility and equipment maintenance: Preventive Maintenance (PM): Scheduled inspections, functional cleanings, and routine servicing to prevent unexpected failures. Unscheduled Maintenance (UM): Repairs for non-critical unexpected failures. The contractor must submit a cost estimate within 14 days and complete the work within 45 days of approval. Emergency Maintenance (EM): 24/7 immediate response for issues threatening life, safety, or critical operations (e.g., refrigeration loss). Technicians must be on-site within 3 hours. For repairs over €3,000, the contractor must stabilize the issue and await government approval before completing the full repair. Operation and Personnel Requirements: Qualified Workforce: The contractor must provide qualified, English-speaking personnel (including a 24/7 Contract Manager) and maintain the internal workforce capacity to complete at least 70% of all requested work without subcontracting. System Tracking: All work orders, estimates, and deliverables must be tracked exclusively through the government's web-based Service Order Management System (SOMS). Base Access & Coordination: The contractor must manage installation access passes for its direct employees and conduct brief, daily check-ins with store management to coordinate work around retail operations. Compliance and Quality Assurance: Reporting: The contractor must submit an initial 100% equipment inventory (updated quarterly), monthly maintenance findings, and an annual refrigerant leak report. Safety & Quality Plans: Comprehensive Safety and Quality Control Plans (QCP) must be submitted shortly after contract award to ensure adherence to commercial standards and EU regulations.
Classifications
Documents (21)
- A.15.01.03.04 Annex D Inventory label instructions WIE.pdf.pdf15 KBNot yet available
- A.15.01.03.12 Solicitation Attachment 3 Sample Work Orders.xlsx.xlsx25 KBNot yet available
- A.15.01.01 Solicitation Amendment (HQC01026QE021 A0001).pdf.pdf145 KBNot yet available
- A.15.01.03.09 Annex I Contractor Provided Work Order System.pdf.pdf154 KBNot yet available
- A.15.01.03.11 Solicitation Attachment 2 Site Visit Information.pdf.pdf308 KBNot yet available
- A.15.01.03.03 Annex C Current inventory WIE.xlsx.xlsx19 KBNot yet available
- A.15.01.03.08 Annex H Performance Requirement Summary WIE.xlsx.xlsx12 KBNot yet available
- A.15.01.03.15 Solicitation Attachment 6 Questions and Government Response.pdf.pdf108 KBNot yet available
- A.15.01.01 Solicitation Amendment (HQC01026QE021A0004).pdf.pdf297 KBNot yet available
- A.15.01.01 Solicitation Amendment (HQC01026QE021A0002).pdf.pdf266 KBNot yet available
- A.15.01.03.14 Solicitation Attachment 5 Site Visit Map.pdf.pdf226 KBNot yet available
- A.15.01.03 Solicitation (HQC01026QE021).pdf.pdf626 KBNot yet available
- A.15.01.03.16 Solicitation Attachment 7 Additional Questions and Government Response.pdf.pdf217 KBNot yet available
- A.15.01.01 Solicitation Amendment (HQC01026QE021A0003).pdf.pdf458 KBNot yet available
- A.15.01.03.06 Annex F Inventory change instructions WIE.pdf.pdf179 KBNot yet available
- A.15.01.03.05 Annex E Emergency Criteria WIE.pdf.pdf104 KBNot yet available
- A.15.01.03.13 Solicitation Attachment 4 Solicitation Helpdesk Information.pdf.pdf54 KBNot yet available
- A.15.01.03.01 Annex A - Items that may require repair.xlsx.xlsx16 KBNot yet available
- A.15.01.03.02 Annex B items excluded from contract WIE.xlsx.xlsx13 KBNot yet available
- A.15.01.03.07 Annex G delivery matrix WIE.xlsx.xlsx9 KBNot yet available
- A.15.01.03.10 Updated Solicitation Attachment 1 Pricing Worksheet.xlsx.xlsx54 KBNot yet available
Contacts
Similar contracts
- Bakersfield National Cemetery Gravesite ExpansionCaliforniaDue Sep 18, 2026
- Sliding Gate Safety Deficiencies RemediationOkinawaDue Aug 27, 2026
- Elevator Modernization SB B777, B778, and WAAF B901HawaiiDue Aug 25, 2026
- Z--SFSC Road and Parking Lot improvementsDue Aug 17, 2026
- Installation of four Exterior Shading SystemsMassachusettsDue Aug 24, 2026
- Notice of Intent - Rough River Lake Service Gate Vent and Floatwell LiningDue Aug 27, 2026